Test ID: LBC
Lamellar Body Count, Amniotic Fluid
Specimen Type
Describes the specimen type needed for testing
Amniotic Fld
Specimen Required
Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.
Collection Container/Tube: Amniotic fluid container
Submission Container/Tube: Plastic vial
Specimen Volume: 10 mL
Collection Instructions: Do not centrifuge.
Additional Information: Centrifuging the specimen may cause erroneous results.
Specimen Minimum Volume
Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.
9.8 mL
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
| Hemolysis | Visible hemolysis, reject |
| Lipemia | NA |
| Icterus | NA |
| Other | NA |
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.
| Specimen Type | Temperature | Time |
|---|---|---|
| Amniotic Fld | Refrigerated (preferred) | 28 days |
| Ambient | 7 days |