Test ID: 9819
Hematoxylin-Eosin-Mayer's Progressive Stain
Secondary ID
A test code used for billing and in test definitions created prior to November 2011
9819
NY State Approved
Indicates the status of NY State approval and if the test is orderable for NY State clients.
Yes
Method Name
A short description of the method used to perform the test
Includes pathology consultation charged separately.
Reporting Name
A shorter/abbreviated version of the Published Name for a test; an abbreviated test name
Hematoxylin-Eosin-Mayers Progres ST
Aliases
Lists additional common names for a test, as an aid in searching
H & E
Hematoxylin-Eosin-Mayers Progres ST
Nuclear and Cytoplasmic
HEMP
Hematoxylin-Eosin-Mayers Progres ST
Nuclear and Cytoplasmic
HEMP
Specimen Type
Describes the specimen type needed for testing
Tissue
Specimen Required
Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.
Specimen Type:
Preferred: Formalin-fixed, paraffin-embedded tissue block
Acceptable: Tissue in formalin
Collection Instructions: Include 1 hematoxylin-and-eosin stained slide.
Specimen Minimum Volume
Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.
NA
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
| Hemolysis | NA |
| Lipemia | NA |
| Icterus | NA |
| Other | NA |
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.
| Specimen Type | Temperature | Time |
|---|---|---|
| Tissue | Ambient | |
Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
The laboratory will provide a pathology consultation and stained slide.
Day(s) and Time(s) Test Performed
Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.
Monday through Friday; 7 a.m.
Analytic Time
Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.
2 days
Maximum Laboratory Time
Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result
5 days
Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded
Until reported
Performing Laboratory Location
The location of the laboratory that performs the test
Rochester
Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.
This test uses a standard method. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements.
CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
88313-Hematoxylin-eosin-Mayer's progressive stain
88325-Pathology consultation
LOINC® Code Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.
| Result ID | Reporting Name | LOINC Code |
|---|---|---|
| 9819 | Hematoxylin-Eosin-Mayers Progres ST | 10790-4 |


