Mobile Site ›
Normal View

Test ID: C5AG
C5 Complement, Antigen, Serum

Secondary ID A test code used for billing and in test definitions created prior to November 2011

9266

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Useful For Suggests clinical disorders or settings where the test may be helpful

Diagnosis of C5 deficiency

 

Investigation of a patient with an absent total complement (CH[50]) level

Method Name A short description of the method used to perform the test

Nephelometry

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

C5 Complement, Antigen, S

Aliases Lists additional common names for a test, as an aid in searching

C5
C5 antigen
C5 level
Complement
Complement level
Fifth Component of Complement

Specimen Type Describes the specimen type needed for testing

Serum

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions:

1. Fasting

2. Spin down and separate serum from clot.

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

0.5 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis

Mild OK; Gross OK

Lipemia

Mild OK; Gross reject

Icterus

Mild OK; Gross OK

Other

NA

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
SerumFrozen (preferred)60 days
 Ambient 7 days
 Refrigerated 7 days

Clinical Information Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Complement proteins are components of the innate immune system. There are 3 pathways to complement activation:1) the classic pathway, 2) the alternative (or properdin) pathway, and 3) the lectin activation (mannan-binding protein, [MBP]) pathway. The classic pathway of the complement system is composed of a series of proteins that are activated in response to the presence of immune complexes. The activation process results in the generation of peptides that are chemotactic for neutrophils and that bind to immune complexes and complement receptors. The end result of the complement activation cascade is the formation of the lytic membrane attack complex (MAC).

  

The absence of early components (C1-C4) of the complement cascade results in the inability of immune complexes to activate the cascade. Patients with deficiencies of the early complement proteins are unable to clear immune complexes or to generate lytic activity. These patients have increased susceptibility to infections with encapsulated microorganisms. They may also have symptoms that suggest autoimmune disease and complement deficiency may be an etiologic factor in the development of autoimmune disease.  

 

More than 30 cases of C5 deficiency have been reported. Most of these patients have neisserial infections.

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

10.6-26.3 mg/dL

Interpretation Provides information to assist in interpretation of the test results

Low levels of complement may be due to inherited deficiencies, acquired deficiencies, or due to complement consumption (eg, as a consequence of infectious or autoimmune processes).  

 

Absent C5 levels in the presence of normal C3 and C4 values are consistent with a C5 deficiency. Absent C5 levels in the presence of low C3 and C4 values suggests complement consumption.

 

A small number of cases have been described in which the complement protein is present but is non functional. These rare cases require a functional assay to detect the deficiency C5FX/83392 C5 Complement, Functional, Serum).

Cautions Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

The total complement assay (COM/8167 Complement, Total, Serum) should be used as a screen for suspected complement deficiencies before ordering individual complement component assays. A deficiency of an individual component of the complement cascade will result in an undetectable total complement level.

Clinical Reference Provides recommendations for further in-depth reading of a clinical nature

1. Sonntag J, Brandenburg U, Polzehl D, et al: Complement systems in healthy term newborns: reference values in umbilical cord blood. Pediatr Dev Pathol 1998;1:131-135

2. Prellner K, Sjoholm AG, Truedsson L: Concentrations of C1q, factor B, factor D and properdin in healthy children, and the age-related presence of circulating C1r-C1s complexes. Acta Peidiatr Scand 1987;76:939-943

3. Davis ML, Austin C, Messmer BL, et al: IFCC-standardization pediatric reference intervals for 10 serum proteins using the Beckman Array 360 system. Clin Biochem 1996;29,5:489-492

4. Gaither TA, Frank MM: Complement. In Clinical Diagnosis and Management by Laboratory Methods. 17th edition. Edited by JB Henry. Philadelphia, WB Saunders Company, 1984, pp 879-892

5. O'Neil KM: Complement defiency. Clin Rev Allergy Immunol 2000;19:83-108

6. Frank MM: Complement deficiencies. Pediatr Clin North Am 2000;47(6):1339-1354

Method Description Describes how the test is performed and provides a method-specific reference

C5 complement antigen is measured by immunonephelometry. Antiserum to C5 is mixed with patient serum, the light scatter resulting from the antibody interaction with C5 is measured, and the signal is compared to standard concentrations of C5. (Unpublished Mayo information; Siemens Nephelometer II Operator’s Instruction Manual Version 2, 1999)

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Monday through Saturday; Continuous with a 3 p.m. cutoff

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

Same day/1 day

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

3 days

Specimen Retention Time Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

7 days

Performing Laboratory Location The location of the laboratory that performs the test

Rochester

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test was developed using an analyte specific reagent. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the U.S. Food and Drug Administration.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

86160

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
C5AGC5 Complement, Antigen, S4505-4