Mobile Site ›
Normal View

Test ID: FNEOP
Neopterin

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Method Name A short description of the method used to perform the test

Radioimmunoassay (RIA)

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Neopterin, Serum

Aliases Lists additional common names for a test, as an aid in searching

Neopterin, Serum FORWARD

Specimen Type Describes the specimen type needed for testing

Serum

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Draw blood in a plain, red-top tube(s). (Serum gel tube is also acceptable.) Spin down and send 1 mL serum frozen in amber vial (Supply T192) to protect from light, freeze immediately.

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

0.2 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis

NA

Thawing

NA

Lipemia

NA

Icterus

NA

Other

Not light protected

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
SerumFrozen (preferred)30 days
 Refrigerated 24 hours

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Reference Range:  <15 nmol/L

 

Test Performed By:   Quest Diagnostics Nichols Institute

                                33608 Ortega Highway

                                San Juan Capistrano, CA 92690-6130          

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Wednesday

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

1 day

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

10 days

Performing Laboratory Location The location of the laboratory that performs the test

Quest Diagnostics/Nichols Institute

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test was performed using a kit that has not been approved or cleared by the FDA. The analytical performance characteristics of this test have been determined by Quest Diagnostics' Nichols Institute, San Juan Capistrano. This test should not be used for diagnosis without confirmation by other medically established means.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

83519

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
Z1568Neopterin, SerumIn Process