Angiotensin I, Plasma

Secondary ID A test code used for billing and in test definitions created prior to November 2011

90429

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

No

Method Name A short description of the method used to perform the test

Direct Radioimmunoassay (RIA)

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Angiotensin I, P

Aliases Lists additional common names for a test, as an aid in searching

Angiotensin I, Plasma FORWARD

Specimen Type Describes the specimen type needed for testing

Plasma EDTA

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Draw blood in a lavender-top (EDTA) tube(s). Separate plasma

from cells immediately after draw, and send 3 mL of EDTA

plasma frozen in plastic vial.

Note:    1. Patient should be on a normal sodium diet, 110 mEq

               of sodium. Patient should be in a recumbent posture for

               at least 30 minutes prior to drawing specimen.

            2. Diuretics, mineralocorticoids, glucocorticoids,

                estrogens, oral contraceptives, adrenocorticotropic

                hormone medications, sodium, potassium, and posture

                all affect angiotensin levels.

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

1 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Specimens other than

Plasma

Anticoagulants other than

EDTA

Hemolysis

NA

Thawing

Warm reject; Cold reject

Lipemia

NA

Icteric

NA

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
Plasma EDTAFrozen

Clinical Information Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Angiotensin I is a ten amino acid peptide formed by Renin cleavage of

Angiotensinogen (Renin Substrate). Angiotensin I has little biological

activity except that high levels can stimulate Catecholamine production.

It is metabolized to its biologically  active byproduct Angiotensin II by

Angiotensin Converting Enzyme (ACE). The formation of Angiotensin I is

controlled by negative feedback of Angiotensin II and II on Renin

release and by Aldosterone concentration. Levels of Angiotensin I are

increased in many types of hypertension. Angiotensin I levels are used

to determine Renin activity. Angiotensin I is excreted directly into the

urine.

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Up to 25 pg/mL

 

This test was performed using a kit that has not been cleared or

approved by the FDA and is designated as research use only.

The analytic performance characteristics of this test have been

determined by Inter Science Institute. This test is not intended for

diagnosis or patient management decisions without confirmation

by other medically established means.

 

Test Performed by: Inter Science Institute

                                       944 West Hyde Park Blvd.

                                       Inglewood, CA 90302

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Batched weekly

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

5 - 7 working days

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

7 - 9 working days

Performing Laboratory Location The location of the laboratory that performs the test

Inter Science Institute

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test was performed using a kit that has not been cleared or approved by the FDA and is designated as research use only. The analytic performance characteristics of this test have been determined by Inter Science Institute. This test is not intended for diagnosis or patient management decisions without confirmation by other medically established means.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

82164

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
Z0939Angiotensin I, P1858-0