Test ID: FCHLM
Chlordane and Metabolites, Serum/Plasma

Secondary ID A test code used for billing and in test definitions created prior to November 2011

90343

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Method Name A short description of the method used to perform the test

Gas Chromatography (GC)

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Chlordane and Metabolites

Aliases Lists additional common names for a test, as an aid in searching

Alpha Chlordane FORWARD
Chlordane FORWARD
Chlordane + Metabolites FORWARD
Octachlor FORWARD
Toxichlor FORWARD

Specimen Type Describes the specimen type needed for testing

Varies

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Submit only 1 of the following specimens:

 

Preferred:

Serum

Draw blood in a plain, red-top tube(s).  (Serum gel tube is not

acceptable.) Spin down and send 3 mL of serum refrigerated.

Note:    1. Indicate serum on report form.

                  2. Label specimen appropriately (serum).

                 

Alternate:

Plasma

Draw blood in a lavender-top (EDTA) tube(s). (Plasma gel tube is not

acceptable.) Spin down and send 3 mL of EDTA plasma refrigerated.

Note:    1. Indicate plasma on report form.

                2. Label specimen appropriately (plasma). 

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

1.2 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Specimens other than

Serum, plasma

Anticoagulants other than

Plain red-top, EDTA

Hemolysis

NA

Thawing

Warm OK; Cold OK

Lipemia

NA

Icteric

NA

 

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
VariesRefrigerated (preferred)14 days
 Ambient 14 days
 Frozen 14 days

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Reporting limit determined each analysis

 

Alpha-Chlordane

    Synonym(s): Cis-Chlordane

    Results reported in ppb

 

Gamma-Chlordane

   Synonym(s): Trans-Chlordane

   Results reported in ppb

 

Trans-Nonachlor

   Synonym(s): Chlordane Component

   Results reported in ppb

 

Heptaclorepoxide

    Synonym(s): Chlordane Metabolite

    Results reported in ppb

 

Oxychlordane

    Synonym(s): Chlordane Metabolite

    Results reported in ppb

 

Heptchlor

    Synonym(s): Chlordane Component

    Results reported in ppb

 

  No reference data available.

 

Test Performed By: NMS Labs

                                       3701 Welsh Road

                                       P.O. Box 433A

                                       Willow Grove, PA 19090-0437

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Tuesday and Friday

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

3 days

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

5 - 9 days

Performing Laboratory Location The location of the laboratory that performs the test

NMS Labs

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

82441

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
Z1445Alpha-Chlordane11091-6
Z1858Reporting LimitIn Process
Z1466Gamma-Chlordane11096-5
Z1304Reporting LimitIn Process
Z1461Trans-Nonachlor23937-6
Z1877Reporting LimitIn Process
Z1462Heptachlorepoxide9473-0
Z1301Reporting LimitIn Process
Z1463Oxychlordane21437-9
Z1302Reporting LimitIn Process
Z1464Heptachlor9472-2
Z1303Reporting LimitIn Process