Mobile Site ›
Normal View

Test ID: FBOMB
Bombesin

Secondary ID A test code used for billing and in test definitions created prior to November 2011

90174

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

No

Method Name A short description of the method used to perform the test

Direct Radioimmunoassay (RIA)

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Bombesin (Plasma)

Aliases Lists additional common names for a test, as an aid in searching

Bombesin FORWARD

Specimen Type Describes the specimen type needed for testing

GI Plasma

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Collect 10 mL of blood in special tube containing G.I. Preservative

(MML supply number T125). Specimen should be separated and

3 mL plasma frozen as soon as possible.

Patient preparation:

           1)  Patient should be fasting 10-12 hours prior to collection.

              2)  Antacid medication or medications that affect intestinal

                    motility should be discontinued, if possible, for at least

                   48 hours prior to specimen collection.

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

1.0 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Specimens other than

Plasma

Anticoagulants other than

Special GI preservative (MML supply T125)

Hemolysis

NA

Thawing

Warm reject; Cold reject

Lipemia

NA

Icteric

NA

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
GI PlasmaFrozen30 days

Clinical Information Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Bombesin is a 14 amino acid peptide with strong Gastrin and gastric acid

releasing properties. Bombesin also increases pancreatic enzyme output.

Bombesin is found in high concentrations in the lung and has been proposed

as a marker for oat-cell carcinoma. Bombesin hypersecretion has been

associated with several physiological effects including anorexia, hypothermia,

and hyperglycemia. It is also increased in small lung cell carcinoma and

tumors of the APUD series. Bombesin infusion increases Neurotensin,

Gastric Inhibitory Polypeptide and Enteroglucagon levels, but has no effect

on pancreatic Glucagon. 

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

50-250 pg/mL

 

This test was developed and its performance characteristics determined by Inter Science Institute. It has not been cleared or approved by the US Food and Drug Administration. The FDA has determined that such clearance or approval is not necessary.

 

Test Performed by: Inter Science Inst

                                       944 West Hyde Park

                                       Inglewood, CA 90302 

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Monday through Friday

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

28 days

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

30 - 32 days

Performing Laboratory Location The location of the laboratory that performs the test

Inter Science Institute

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test was developed and its performance characteristics determined by Inter Science Institute. It has not been cleared or approved by the US Food and Drug Administration. The FDA has determined that such clearance or approval is not necessary.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

83519

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
Z0935Bombesin, (Plasma)10874-6