Mobile Site ›
Normal View

Test ID: SSF1
Nocardia Stain

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Method Name A short description of the method used to perform the test

Modified Kinyoun Stain

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Nocardia Stain

Aliases Lists additional common names for a test, as an aid in searching

Fungal Smear
Nocardia Stain
Special Stain for Fungus, Nocardia
Aerobic Actinomycetes

Specimen Type Describes the specimen type needed for testing

Varies

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Container/Tube: Sterile container

Specimen Volume: Entire collection

Collection Instructions: Collect a raw specimen.

Additional Information: Specimen source is required.

Forms: If not ordering electronically, submit a Microbiology Request Form (Supply T244) with the specimen.

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis

NA

Lipemia

NA

Icterus

NA

Other

Blood; bone marrow; fixed tissue; viral transport media (including but not limited to M4, M5, BD viral transport media, thioglycolate broth); environmental specimen; wood shaft; or charcoal swab

 

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
VariesRefrigerated (preferred)7 days
 Ambient 7 days

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

The laboratory will provide an interpretive report.

Reported as positive or negative.

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Monday through Sunday Continuously

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

1 day

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

2 days

Specimen Retention Time Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

Raw specimens saved 2-14 days.

Performing Laboratory Location The location of the laboratory that performs the test

Rochester

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test uses a standard method. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

87206

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
SSF1Nocardia StainIn Process