Test ID: URAU
Urea, Urine

Secondary ID A test code used for billing and in test definitions created prior to November 2011

8330

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Useful For Suggests clinical disorders or settings where the test may be helpful

Assessment of protein intake and/or nitrogen balance.  

Special Instructions and Forms Describes specimen collection and preparation information, test algorithms, and other information pertinent to test. Also includes pertinent information and consent forms to be used when requesting a particular test

Method Name A short description of the method used to perform the test

Kinetic UV Assay 

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Urea, U

Aliases Lists additional common names for a test, as an aid in searching

BUN

Specimen Type Describes the specimen type needed for testing

Urine

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Container/Tube: Plastic, 6-mL tube (Supply T465)

Specimen Volume: 5 mL

Collection Instructions:

1. Collect urine for 24 hours.

2. Add 10 g of boric acid as preservative at start of collection. (If boric acid is not available, refrigerate specimen during collection.)

3. Mix well before taking aliquot.

Additional Information:

1. 24-hour volume is required.

2. See Urine Preservatives in Special Instructions for multiple collections.

 

Urine Preservative Collection Options

Ambient:

No

Refrigerated:

Yes

Frozen:

Yes

6N HCl:

Yes

50% Acetic Acid:

Yes

Na2CO3:

Yes

Toluene:

Yes

6N HNO3:

Yes

Boric Acid:

Preferred

Thymol:

Yes

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

1 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis

NA

Lipemia

NA

Icterus

NA

Other

NA

 

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
UrineRefrigerated (preferred)
 Frozen 

Clinical Information Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Urea is a low molecular weight substance (Mol. Wt.=60) that is freely filtered by glomeruli and the majority is excreted into the urine, although variable amounts are reabsorbed along the nephron. It is the major end product of protein metabolism in humans and other mammals. Approximately 50% of urinary solute excretion and 90% to 95% of total nitrogen excretion is composed of urea under normal conditions. Factors which tend to increase urea excretion include increases in glomerular filtration rate, increased dietary protein intake, protein catabolic conditions, and water diuretic states. Factors which reduce urea excretion include low protein intake and conditions which result in low urine output (eg, dehydration).

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

10-35 g/specimen

Interpretation Provides information to assist in interpretation of the test results

Because multiple factors (glomerular filtration rate, dietary protein intake, protein catabolic rate, hydration state, etc.) can independently affect the urinary excretion of urea, all of these factors must by taken into account when interpreting the results.

Clinical Reference Provides recommendations for further in-depth reading of a clinical nature

Bankir L, Trinh-Trang-Tan MM: Urea and The Kidney. In The Kidney. 6th edition. Edited by BM Brenner. Philadelphia, WB Saunders Company, 2000

Method Description Describes how the test is performed and provides a method-specific reference

Urea is hydrolyzed by urease to form ammonia and CO2. The ammonia formed then reacts with keotglutarate and NADH in the presence of GLDH to yield glutamate and NAD+. The decrease in absorbence is due to consumption of NADH is measured kinetically at 340 nm. (Package insert: Roche Urea; BUN Package insert: Roche Diagnostic Corp, Indianapolis IN)

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Monday through Sunday; Continuously  

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

Same day/1 day

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

1 day

Specimen Retention Time Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

7 days

Performing Laboratory Location The location of the laboratory that performs the test

Rochester

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

84540

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
UREAUrea, U48999-7
TM33Collection Duration13362-9
VL31Urine Volume3167-4
URECNUrea Concentration63481-6