Mobile Site ›
Normal View

Test ID: EBF
Electrophoresis, Protein, Body Fluid

Secondary ID A test code used for billing and in test definitions created prior to November 2011

8274

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Profile Information A profile is a group of laboratory tests that are ordered and performed together under a single Mayo Test ID. Profile information lists the test performed, inclusive of the test fee, when a profile is ordered and includes reporting names and individual availability.

Test IDReporting NameAvailable SeparatelyAlways Performed
FLD4Fluid TypeNoYes
TP1Protein, TotalNoYes
ELPBFProtein Electrophoresis, BFNoYes

Method Name A short description of the method used to perform the test

Agarose Gel Electrophoresis

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Electrophoresis, Protein, BF

Aliases Lists additional common names for a test, as an aid in searching

Albumin, Body Fluid
Electrophoresis, Protein, Spinal Fluid
Gamma Globulin
Protein Electrophoresis, Body Fluid

Specimen Type Describes the specimen type needed for testing

Body Fluid

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Container/Tube: Sterile container

Specimen Volume: 10 mL

Collection Instructions: Centrifuge to remove any cellular material.

Additional Information: Indicate specimen source.

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

4 mL*

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis

NA

Lipemia

NA

Icterus

NA

Other

NA

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
Body FluidRefrigerated (preferred)7 days
 Frozen 14 days
 Ambient 72 hours

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Not applicable

Cautions Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

No significant cautionary statements

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Monday through Saturday; 12 p.m.

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

1 day

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

3 days

Specimen Retention Time Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

7 days

Performing Laboratory Location The location of the laboratory that performs the test

Rochester

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test has been modified from the manufacturer’s instructions. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

84166

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
2802Albumin12174-9
TP1Protein, Total2881-1
FLD4Fluid Type14725-6
2803Alpha 1-Globulin17812-9
2804Alpha 2-Globulin17814-5
2805Beta-Globulin17816-0
2806Gamma-Globulin17818-6