Test ID: C1ES
C1 Esterase (C1ES) Inhibitor Antigen, Serum
Secondary ID
A test code used for billing and in test definitions created prior to November 2011
NY State Approved
Indicates the status of NY State approval and if the test is orderable for NY State clients.
Useful For
Suggests clinical disorders or settings where the test may be helpful
Diagnosis of hereditary angioedema
Monitoring levels of C1 esterase inhibitor in response to therapy
Method Name
A short description of the method used to perform the test
Nephelometry
Reporting Name
A shorter/abbreviated version of the Published Name for a test; an abbreviated test name
Aliases
Lists additional common names for a test, as an aid in searching
C1 Esterase Inhibitor Quantitative
C1 inhibitor level
Specimen Type
Describes the specimen type needed for testing
Specimen Required
Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.
Collection Container/Tube:
Preferred: Red top
Acceptable: Serum gel
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions: Fasting preferred but not required.
Specimen Minimum Volume
Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
| Hemolysis | Mild OK; Gross OK |
| Lipemia | Mild OK; Gross reject |
| Icterus | Mild OK; Gross OK |
| Other | NA |
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum | Frozen (preferred) | 14 days |
| Ambient | 72 hours | |
| Refrigerated | 72 hours |
Clinical Information
Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test
C1 esterase inhibitor blocks the activation of C1 (first component of the complement cascade) to its active form. The deficiency of C1 esterase inhibitor results in the inappropriate activation of C1 and the subsequent release of an activation peptide from C2 with kinin-like activity. This kinin-like peptide enhances vascular permeability. C1 esterase inhibitor deficiency results in hereditary or acquired angioedema. This disease is an autosomal dominant inherited condition, in which exhaustion of the abnormally low levels of C1 esterase inhibitor results in C1 activation, breakdown of C2 and C4, and subsequent acute edema of subcutaneous tissue, the gastrointestinal tract, or the upper respiratory tract. The disease responds to attenuated androgens.
Because 15% of C1 inhibitor deficiencies have nonfunctional protein, some patients will have abnormal functional results (FC1EQ/81493 C1 Esterase Inhibitor, Functional Assay, Serum) in the presence of normal (or elevated) antigen levels.
Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
19-37 mg/dL
Interpretation
Provides information to assist in interpretation of the test results
Abnormally low results are consistent with a heterozygous C1 esterase inhibitor deficiency and hereditary angioedema.
Fifteen percent of hereditary angioedema patients have a normal or elevated level but nonfunctional C1 esterase inhibitor protein. Detection of these patients requires a functional measurement of C1 esterase inhibitor; FC1EQ/81493 C1 Esterase Inhibitor, Functional Assay, Serum.
Measurement of C1q antigen levels; C1Q/8851 Complement C1q, Serum, is key to the differential diagnoses of acquired or hereditary angioedema. Those patients with the hereditary form of the disease will have normal levels of C1q, while those with the acquired form of the disease will have low levels.
Studies in children show that adult levels of C1 inhibitor are reached by 6 months of age.
Cautions
Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances
Quantitation of specific proteins by nephelometric means may not be possible in lipemic sera due to the extreme light scattering properties of the specimen. Turbidity and particles in the specimen may result in extraneous light scattering signals, resulting in variable specimen analysis.
Clinical Reference
Provides recommendations for further in-depth reading of a clinical nature
1. Frank MM: Complement deficiencies. Pediatr Clin North Am 2000;47(6):1339-1354
2. Gelfand JA, Boss GR, Conley CL, et al: Acquired C1 esterase inhibitor deficiency and angioedema: a review. Medicine 1979;58(4):321-328
3. Rosen FS, Alper CA, Pensky J, et al: Genetically determined heterogeneity of the C1 esterase inhibitor in patients with hereditary angioneurotic edema. J Clin Invest 1971;50(10):2143-2149
4. Frigas E: Angioedema with acquired deficiency of the C1 inhibitor: a constellation of syndromes. Mayo Clin Proc 1989;64:1269-1275
5. Soldin SJ, Hicks JM, Bailey J, et al: Pediatric reference ranges for estradiol and C1 esterase inhibitor. Clin Chem 1998;44(6s):A17
Method Description
Describes how the test is performed and provides a method-specific reference
C1 esterase inhibitor complement antigen (C1ES) is measured by immunonephelometry. Antiserum to C1ES is mixed with patient serum, the light scatter resulting from the antibody interaction with C1ES is measured, and the signal is compared to standard concentrations of C1ES. (Instruction Manual: Siemens Nephelometer II Operations, 2005)
Day(s) and Time(s) Test Performed
Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.
Monday through Saturday; Continuously until 3 p.m.
Analytic Time
Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.
Maximum Laboratory Time
Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result
Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded
Performing Laboratory Location
The location of the laboratory that performs the test
Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.
CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
83520
LOINC® Code Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.
| Result ID | Reporting Name | LOINC Code |
|---|---|---|
| C1ES | C1 Esterase Inhibitor Antigen, S | 4477-6 |