Mobile Site ›
Normal View

Test ID: GANC
Ganciclovir, Serum

Secondary ID A test code used for billing and in test definitions created prior to November 2011

80140

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Useful For Suggests clinical disorders or settings where the test may be helpful

Monitoring patients on ganciclovir

Method Name A short description of the method used to perform the test

High-Performance Liquid Chromatography (HPLC)

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Ganciclovir, S

Aliases Lists additional common names for a test, as an aid in searching

Valcyte
Valganciclovir
9-[(1,3-Dihydroxy-2-propoxy)methyl]guanine (DHPG)
DHPG (9-[(1,3-Dihydroxy-2-propoxy)methyl]guanine)

Specimen Type Describes the specimen type needed for testing

Serum Red

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Collection Container/Tube: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 1 mL

Collection Instructions: 

1. Serum for a peak level should be drawn 30 to 60 minutes after dosing. Serum for a trough level should be drawn no more than 30 minutes before the next dose.

2. Spin down within 2 hours of draw.

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

0.3 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis

Mild OK; Gross reject

Lipemia

Mild OK; Gross reject

Icterus

Mild OK; Gross reject

Other

Serum gel tube

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
Serum RedFrozen14 days

Clinical Information Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

Ganciclovir, an analog of acylcovir, demonstrates inhibitory action against some viruses including herpes virus, cytomegalovirus, and HIV. Therapeutic ranges have not been well-established for ganciclovir; current ranges are based on typical values seen during ganciclovir therapy and do not correlate well to toxicity or outcome. Monitoring of ganciclovir serum concentrations may be most useful in guiding therapy in patients with renal dysfunction. Myelosuppression is the major dose-limiting side effect of ganciclovir.

 

Valcyte (valganciclovir) is an oral pro-drug of ganciclovir ester. It is immediately converted to ganciclovir once it enters the bloodstream. The oral dose is designed to deliver ganciclovir equivalent to intravenous ganciclovir at 5 mg/kg.

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Trough: 1.0-3.0 mcg/mL

Peak: 3.0-12.5 mcg/mL

Interpretation Provides information to assist in interpretation of the test results

Serum concentrations of ganciclovir do not correlate well to toxicity or efficacy. Peak and trough levels provided are representative of typical serum concentrations seen during therapy, but individual values must be interpreted in conjunction with the clinical status of the individual patient and the specific characteristics of the infecting microorganism.

Cautions Discusses conditions that may cause diagnostic confusion, including improper specimen collection and handling, inappropriate test selection, and interfering substances

Usage should be discontinued if absolute neutropenia develops.

Clinical Reference Provides recommendations for further in-depth reading of a clinical nature

1. Perrottet N, Decosterd LA, Meylan P, et al: Valganciclovir in adult solid organ transplant recipients: paharmacokinetic and pharmacodynamic characteristics and clinical interpretation of plasma concentration measurements. Clin Pharmacokinet 2009;48(6):399-418

2. Uges D: Therapeutic and toxic drug concentrations, The International Association of Forensic Toxicologists. Dec 2009. Retrieved 12/09; Available from URL: www.tiaft.org

Method Description Describes how the test is performed and provides a method-specific reference

High-performance liquid chromatography (HPLC).(Unpublished Mayo method)

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Monday; 9:00 a.m.

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

2 days

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

9 days

Specimen Retention Time Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location The location of the laboratory that performs the test

Rochester

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the U.S. Food and Drug Administration.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

80299

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
80140Ganciclovir, S15367-6