Test ID: ADMIS
ADAMTS13 Inhibitor Screen Assay
NY State Approved
Indicates the status of NY State approval and if the test is orderable for NY State clients.
Conditional
Method Name
A short description of the method used to perform the test
ADMIS/61213 – not orderable only performed and charged as a reflex of profile ADM13/61212.
Reporting Name
A shorter/abbreviated version of the Published Name for a test; an abbreviated test name
ADAMTS13 Inhibitor Screen
Specimen Type
Describes the specimen type needed for testing
Plasma Na Cit
Specimen Required
Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.
Only orderable as part of a profile. For further information see ADM13/61212 ADAMTS13 Activity and Bethesda Inhibitor Titer Profile.
Specimen Minimum Volume
Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.
2 mL
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
| Hemolysis | Mild OK; Gross reject |
| Lipemia | Mild OK; Gross reject |
| Icterus | Mild OK; Gross reject |
| Other | NA |
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.
| Specimen Type | Temperature | Time |
|---|---|---|
| Plasma Na Cit | Frozen | 14 days |
Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
Negative
Specimen Retention Time
Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded
14 Days
Performing Laboratory Location
The location of the laboratory that performs the test
Rochester
Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.
This test uses a reagent or kit labeled by the manufacturer as Research Use Only. Its performance characteristics were determined by Mayo Clinic in a manner consistent with CLIA requirements. This test has not been cleared or approved by the U.S. Food and Drug Administration.
CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
85335
LOINC® Code Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.
| Result ID | Reporting Name | LOINC Code |
|---|---|---|
| 61213 | ADAMTS13 Inhibitor Screen | In Process |