Test ID: FCP12
Cytokine Panel 12 by MAFD
NY State Approved
Indicates the status of NY State approval and if the test is orderable for NY State clients.
Method Name
A short description of the method used to perform the test
Quantitative Multiplex Bead Assay
Reporting Name
A shorter/abbreviated version of the Published Name for a test; an abbreviated test name
Aliases
Lists additional common names for a test, as an aid in searching
IL 12 Receptor FORWARD
IL2 Receptor FORWARD
IFN FORWARD
IFN gamma FORWARD
IL 4 FORWARD
IL 5 FORWARD
IL 10 FORWARD
IL 13 FORWARD
IL 1 beta FORWARD
IL 6 FORWARD
IL 8 FORWARD
IL 2 FORWARD
TNF alpha FORWARD
Specimen Type
Describes the specimen type needed for testing
Specimen Required
Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.
Submit only 1 of the following:
Serum
Draw blood in a plain, red-top tube(s). (Serum gel tube is acceptable.) Send 1 mL of serum frozen in a plastic vial.
Plasma
Draw blood in a green-top (heparin) tube(s). Send 1 mL of plasma frozen in a plastic vial.
Note: Critical frozen. Additional specimens must be submitted when multiple tests are ordered.
Specimen Minimum Volume
Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
| Hemolysis: | NA |
| Thawing: | Warm Reject; Cold Reject |
| Lipemia: | NA |
| Icterus: | NA |
| Other: | Heat-inactivated, refrigerated or contaminated specimens are unacceptable. |
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.
| Specimen Type | Temperature | Time |
|---|---|---|
| Varies | Frozen | 365 days |
Reference Values
Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.
Interleukin 2 by MAFD 0 – 12 pg/mL
Interleukin 2 Receptor (Soluble) by MAFD 0 – 1033 pg/mL
Interleukin 12 by MAFD 0 – 6 pg/mL
Interferon gamma by MAFD 0 – 5 pg/mL
Interleukin 4 by MAFD 0 – 5 pg/mL
Interleukin 5 by MAFD 0 – 5 pg/mL
Interleukin 10 by MAFD 0 – 18 pg/mL
Interleukin 13 by MAFD 0 – 5 pg/mL
Interleukin 1 beta by MAFD 0 – 36 pg/mL
Interleukin 6 by MAFD 0 – 5 pg/mL
Interleukin 8 by MAFD 0 – 5 pg/mL
Tumor Necrosis Factor – alpha 0 – 22 pg/mL
Results are to be used for research purposes or in attempts to understand the pathophysiology of immune, infectious, or inflammatory disorders.
Test Performed by: ARUP Laboratories
500 Chipeta Way
St. Lake City, UT 84108
Day(s) and Time(s) Test Performed
Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.
Monday, Wednesday, Friday
Analytic Time
Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.
Maximum Laboratory Time
Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result
Performing Laboratory Location
The location of the laboratory that performs the test
Test Classification
Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.
CPT Code Information
Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.
83520 x12
LOINC® Code Information
Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.
| Result ID | Reporting Name | LOINC Code |
|---|---|---|
| Z2732 | Interleukin 2 by MAFD | In Process |
| Z2721 | Interleukin 2 Receptor by MAFD | In Process |
| Z2722 | Interleukin 12 by MAFD | In Process |
| Z2723 | Interferon gamma by MAFD | In Process |
| Z2724 | Interleukin 4 by MAFD | In Process |
| Z2725 | Interleukin 5 by MAFD | In Process |
| Z2726 | Interleukin 10 by MAFD | In Process |
| Z2727 | Interleukin 13 by MAFD | In Process |
| Z2728 | Interleukin 1 beta by MAFD | In Process |
| Z2729 | Interleukin 6 by MAFD | In Process |
| Z2730 | Interleukin 8 by MAFD | In Process |
| Z2731 | Tumor Necrosis Factor - alpha | In Process |