Mobile Site ›
Normal View

Test ID: FCP12
Cytokine Panel 12 by MAFD

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Method Name A short description of the method used to perform the test

Quantitative Multiplex Bead Assay

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Cytokine Panel 12 by MAFD

Aliases Lists additional common names for a test, as an aid in searching

Cytokine 12 FORWARD
IL 12 Receptor FORWARD
IL2 Receptor FORWARD
IFN FORWARD
IFN gamma FORWARD
IL 4 FORWARD
IL 5 FORWARD
IL 10 FORWARD
IL 13 FORWARD
IL 1 beta FORWARD
IL 6 FORWARD
IL 8 FORWARD
IL 2 FORWARD
TNF alpha FORWARD

Specimen Type Describes the specimen type needed for testing

Varies

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Submit only 1 of the following:

 

Serum

Draw blood in a plain, red-top tube(s). (Serum gel tube is acceptable.) Send 1 mL of serum frozen in a plastic vial.

 

Plasma

Draw blood in a green-top (heparin) tube(s). Send 1 mL of plasma frozen in a plastic vial.

 

Note: Critical frozen. Additional specimens must be submitted when multiple tests are ordered.

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

0.3 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis:

NA

Thawing:

Warm Reject; Cold Reject

Lipemia:

NA

Icterus:

NA

Other:

Heat-inactivated, refrigerated or contaminated specimens are unacceptable.

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
VariesFrozen365 days

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Interleukin 2 by MAFD                                        0 – 12 pg/mL

Interleukin 2 Receptor (Soluble) by MAFD            0 – 1033 pg/mL

Interleukin 12 by MAFD                                      0 – 6 pg/mL

Interferon gamma by MAFD                                0 – 5 pg/mL

Interleukin 4 by MAFD                                        0 – 5 pg/mL

Interleukin 5 by MAFD                                        0 – 5 pg/mL

Interleukin 10 by MAFD                                      0 – 18 pg/mL

Interleukin 13 by MAFD                                      0 – 5 pg/mL

Interleukin 1 beta by MAFD                                 0 – 36 pg/mL

Interleukin 6 by MAFD                                        0 – 5 pg/mL

Interleukin 8 by MAFD                                        0 – 5 pg/mL

Tumor Necrosis Factor – alpha                            0 – 22 pg/mL

 

Results are to be used for research purposes or in attempts to understand the pathophysiology of immune, infectious, or inflammatory disorders.

 

Test Performed by: ARUP Laboratories

                            500 Chipeta Way

                            St. Lake City, UT 84108

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Monday, Wednesday, Friday

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

1 - 4 days

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

3 - 8 days

Performing Laboratory Location The location of the laboratory that performs the test

ARUP Laboratories

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test was developed and its performance characteristics determined by ARUP Laboratories. The U.S. Food and Drug Administration has not approved or cleared this test; however, FDA clearance or approval is not currently required for clinical use. The results are not intended to be used as the sole means for clinical diagnosis or patient management decisions.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

83520 x12

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
Z2732Interleukin 2 by MAFDIn Process
Z2721Interleukin 2 Receptor by MAFDIn Process
Z2722Interleukin 12 by MAFDIn Process
Z2723Interferon gamma by MAFDIn Process
Z2724Interleukin 4 by MAFDIn Process
Z2725Interleukin 5 by MAFDIn Process
Z2726Interleukin 10 by MAFDIn Process
Z2727Interleukin 13 by MAFDIn Process
Z2728Interleukin 1 beta by MAFDIn Process
Z2729Interleukin 6 by MAFDIn Process
Z2730Interleukin 8 by MAFDIn Process
Z2731Tumor Necrosis Factor - alphaIn Process