Squamous Cell Carcinoma Antigen, Serum

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Method Name A short description of the method used to perform the test

Quantitative Enzyme-Linked Immunosorbent Assay (ELISA)

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Squamous Cell Carcinoma

Aliases Lists additional common names for a test, as an aid in searching

SCC Antigen FORWARD

Specimen Type Describes the specimen type needed for testing

Serum

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Draw blood in a plain, red-top tube(s) or serum gel tube(s). Allow serum to clot completely at room temperature. Spin down and send 2 mL serum frozen in a plastic vial.

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

0.3 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis:

NA

Thawing:

Warm reject; Cold reject

Lipemia:

NA

Icterus:

NA

Other:

NA

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
SerumFrozen (preferred)120 days
 Refrigerated 120 days
 Ambient 48 hours

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

0.0-2.2 ng/mL

      

SCC antigen levels alone should not be interpreted as evidence

of the presence or absence of malignant disease. In

patients with known or expected cancer, other tests

and procedures must be considered for diagnosis and

patient management. Results obtained with different

assay methods or kits cannot be used interchangeably.

             

Test Performed By:  ARUP Laboratories

                              500 Chipeta Way

                              Salt Lake City, UT  84108

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Saturday

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

1-8 days

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

3 - 10 days

Performing Laboratory Location The location of the laboratory that performs the test

ARUP Laboratories

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

Analyte Specific Reagents (ASR) are used in many laboratory tests necessary for standard medical care and generally do require U.S. Food and Drug Administration approval. This test was developed and its performance characteristics determined by ARUP Laboratories, Inc. It has not been approved by the U.S. Food and Drug Administration. This test should not be regarded as investigational or for research use.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

86316

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
Z2651Squamous Cell Carcinoma AntibodyIn Process