Mobile Site ›
Normal View

Test ID: FMY3P
Myositis Ab 3 Panel, Extensive

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Method Name A short description of the method used to perform the test

Immunoprecipitation (IPP) and Enzyme Immunoassay (EIA)

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Myositis Ab 3 Panel

Specimen Type Describes the specimen type needed for testing

Varies

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Submit only 1 of the following specimens:

 

Serum

Draw blood in a plain, red-top tube(s). Spin down and send 3 mL of serum refrigerate in plastic vial.

Note: 1. Indicate serum on request form.

         2. Label specimen appropriately (serum).

 

Plasma

Draw blood in a lavender-top (EDTA) tube(s). Spin down and send 3 mL of EDTA plasma refrigerate in plastic  vial.

Note: 1. Indicate plasma on request form.

         2. Label specimen appropriately (plasma).

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Specimens Other Than

Serum, plasma

Anticoagulants Other Than

EDTA

Hemolysis

NA

Thawing

Warm OK; Cold OK

Lipemia

NA

Icteric

NA

 

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
VariesRefrigerated (preferred)7 days
 Frozen 180 days
 Ambient 7 days

Clinical Information Discusses physiology, pathophysiology, and general clinical aspects, as they relate to a laboratory test

  1. Anti-Jo 1 Abs are found in subset of myositis patients characterized by interstitial lung disease, systemic polyarthritis, Raynaud's Phenomena, fever and Mechanic's Hand (anti-synthetase syndrome).
  2. Anti-Jo 1 appears to be a marker for interstitial lung disease in polymyositis.

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Anti-Jo-1 Ab, U1 RNP, SSA52 KD AB, IgG:

 

Reference Range:  Negative

 

Negative                <20 units

Weak Positive          20 - 39 units

Moderate Positive    40 - 80 units

Strong Positive      >80 units

 

Mi-2, PL-12, PL-7, EJ, OJ, SRP, Ku, U2 snRNP, PM/Scl, P140, P155/140, Fibrillarin U3 RNP:

 

Reference Range:  Negative

 

Test Performed by: RDL Reference Laboratory, Inc.

                             10755 Venice Boulevard

                             Los Angeles, CA 90034

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Batched weekly

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

14 days

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

16 - 18 days

Performing Laboratory Location The location of the laboratory that performs the test

RDL Reference Laboratory, Inc.

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test was developed and its performance characteristics validated by RDL Inc. The FDA has determined that approval for this test is not necessary. This is an analyte specific reagent (ASR) test.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

86235-Anti-Jo 1 Ab

83516-MI-2

83516-PL-7

83516-PL-12

83516-EJ

83516-OJ

83516-SRP

83516-KU

83516-U2 SN RNP

83516-P140

83516-P155/140

83516-Fibrillarin U3

86235-PM/SCL

86235-SSA 52 KD AB IgG

86235-U1 RNP

86235-RNP AB

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
Z2577MI-2In Process
Z2578JO-1In Process
Z2579PL-7In Process
Z2580PL-12In Process
Z2581EJIn Process
Z2582OJIn Process
Z2583SRPIn Process
Z2584P155/140In Process
Z2585P140In Process
Z2586KUIn Process
Z2587U1 RNP ABIn Process
Z2588RNP ABIn Process
Z2589PM/SCLIn Process
Z2590Fibrillarin U3In Process
Z2591SSA52 KD Ab, IGGIn Process
Z2592U2 SN RNPIn Process