Mobile Site ›
Normal View

Test ID: FCANA
Candida albicans Antibodies (IgG, IgA, IgM)

Secondary ID A test code used for billing and in test definitions created prior to November 2011

57158

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

No

Method Name A short description of the method used to perform the test

Enzyme-Linked Immunosorbent Assay (ELISA)

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

Candida Albicans Ab (IgG,IgA,IgM)

Specimen Type Describes the specimen type needed for testing

Serum

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Draw blood in a plain, red-top tube(s). Serum gel tube is also acceptable. Spin down and send 1 mL of serum refrigerate.

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

0.2 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Specimens other than

Serum

Anticoagulants other than

NA

Hemolysis

NA

Thawing

Warm OK; Cold OK

Lipemia

NA

Icteric

NA

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
SerumRefrigerated (preferred)14 days
 Frozen 30 days
 Ambient 7 days

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Reference Range:   <1.0

 

Interpretive Criteria:  

                   <1.0   Antibody not detected

           > or = 1.0   Antibody detected

         

Systemic candidiasis is often characterized by markedly

elevated levels of IgG, IgA, and IgM recognizing Candida.

However, interpretation of Candida antibody levels

is complicated by detection of antibodies in 20-30% of healthy

individuals, and blunted antibody responses in immuno-

compromised patients at risk for systemic candidiasis. Candida

antibody results should be considered within the context of clinical

findings and results from other relevant laboratory tests, such as

Candida antigen detection and/or culture.

 

Test Performed by: Focus Diagnostics, Inc.

                             5785 Corporate Avenue

                             Cypress, CA   90630-4750

Day(s) and Time(s) Test Performed Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.

Monday, Thursday

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

1 - 5 days

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

3 - 9 days

Specimen Retention Time Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

6 weeks

Performing Laboratory Location The location of the laboratory that performs the test

Focus Diagnositics, Inc.

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test was developed and its performance characteristics have been determined by Focus Diagnostics. Performance characteristics refer to the analytical performance of the test.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

86628/x3

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
Z2317C. Albicans IgG51539-5
Z2318C. Albicans IgAIn Process
Z2319C. Albicans IgMIn Process