Mobile Site ›
Normal View

Test ID: HSMR
Herpes Simplex Virus (HSV) Antibody, IgM, by Immunofluorescence Assay (IFA), Serum

Secondary ID A test code used for billing and in test definitions created prior to November 2011

26589

NY State Approved Indicates the status of NY State approval and if the test is orderable for NY State clients.

Yes

Testing Algorithm Delineates situation(s) when tests are added to the initial order. This includes reflex and additional tests.

If MHSV/87998 Herpes Simplex Virus (HSV) Antibody Screen, IgM, by EIA, Serum is reactive, then HSMR/26589 Herpes Simplex Virus (HSV) Antibody, IgM, by Immunofluorescence Assay (IFA), Serum will be performed at an additional charge.

Method Name A short description of the method used to perform the test

Immunofluorescence Assay (IFA)

Reporting Name A shorter/abbreviated version of the Published Name for a test; an abbreviated test name

HSV Ab, IgM, S by IFA

Specimen Type Describes the specimen type needed for testing

Serum

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Container/Tube: 

Preferred: Red top

Acceptable: Serum gel

Specimen Volume: 1 mL

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

0.2 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Specimens Other Than:                  

Anticoagulants Other Than:           

Hemolysis:         

Thawing:

Lipemia:

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
SerumRefrigerated (preferred)14 days
 Frozen 14 days

Reference Values Describes reference intervals and additional information for interpretation of test results. May include intervals based on age and sex when appropriate. Intervals are Mayo-derived, unless otherwise designated. If an interpretive report is provided, the reference value field will state this.

Negative

Analytic Time Defines the amount of time it takes the laboratory to setup and perform the test. This is defined in number of days. The shortest interval of time expressed is "same day/1 day," which means the results may be available the same day that the sample is received in the testing laboratory. One day means results are available 1 day after the sample is received in the laboratory.

Same day/1 day

Maximum Laboratory Time Defines the maximum time from specimen receipt at Mayo Medical Laboratories until the release of the test result

3 days

Specimen Retention Time Outlines the length of time after testing that a specimen is kept in the laboratory before it is discarded

14 days

Performing Laboratory Location The location of the laboratory that performs the test

Rochester

Test Classification Provides information regarding the medical device classification for laboratory test kits and reagents. Tests may be classified as cleared or approved by the US Food and Drug Administration (FDA) and used per manufacturer's instructions, or as products that do not undergo full FDA review and approval, and are then labeled as an Analyte Specific Reagent (ASR), Investigation Use Only (IUO) product, or a Research Use Only (RUO) product.

This test has been cleared or approved by the U.S. Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information Provides guidance in determining the appropriate Current Procedural Terminology (CPT) code(s) information for each test or profile. The listed CPT codes reflect Mayo Medical Laboratories interpretation of CPT coding requirements. It is the responsibility of each laboratory to determine correct CPT codes to use for billing.

86694

LOINC® Code Information Provides guidance in determining the Logical Observation Identifiers Names and Codes (LOINC) values for the result codes returned for this test or profile.

Result IDReporting NameLOINC Code
26589HSV Ab, IgM, S by IFA44507-2