Mobile Site ›

61337:
Hereditary Erythrocytosis Mutations

CPT Code Information Current Value

Molecular Interpretation

83890-Automated extraction

83912-Interpretation and Report

 

EPOR Gene, Mutation Analysis, B

83900-Amplification, target, multiplex, first 2 nucleic acid sequences

83904 x 4-Mutation identification by DNA sequencing, single segment, each segment

83909 x 4-Separation and identification by high resolution technique

 

HIF2A Gene, Mutation Analysis, B

83900-Amplification, target, multiplex, first 2 nucleic acid sequences

83904 x 4-Mutation identification by DNA sequencing, single segment, each segment

83909 x 4-Separation and identification by high resolution technique

 

PHD2 Gene, Mutation Analysis, B

83900-Amplification, target, multiplex, first 2 nucleic acid sequences

83901 x 3-Amplification, target, multiplex, each additional nucleic acid sequence beyond 2

83904 x 12-Mutation identification by DNA sequencing, single segment, each segment

83909 x 12-Separation and identification by high resolution technique

 

VHL Full Gene Analysis (if appropriate)

81404-VHL (von Hippel-Lindau tumor suppressor) (eg, von Hippel-Lindau familial cancer syndrome), full gene sequence

81403-VHL (von Hippel-Lindau tumor suppressor) (eg, von Hippel-Lindau familial cancer syndrome), deletion/duplication analysis (if appropriate)

 

For nonparticipating payers:

Von Hippel-Lindau (VHL) Gene, Full Gene Analysis

83892 x 2-Enzymatic digestion

83894-Separation by gel electrophoresis

83900-Amplification, target, multiplex, first 2 nucleic acid sequences

83901 x 4-Amplification, target, multiplex, each additional nucleic acid sequence beyond 2

83912-Interpretation and report

 

VHL Gene Sequencing

83909 x 6

 

VHL Deletion Detection

83900-Amplification, target, multiplex, first 2 nucleic acid sequences (if appropriate)

83901 x 14-Amplification, target, multiplex, each additional nucleic acid sequence beyond 2 (if appropriate)

83909-Separation and identification by high-resolution technique (if appropriate)

83914-Mutation identification by enzymatic ligation or primer extension, single segment, each segment (if appropriate)


CPT Code Information Value Prior to 11/27/2012 1:04pm

Molecular Interpretation

83890-Automated extraction

83912-Interpretation and Report

 

 

EPOR Gene, Mutation Analysis, B

83900-Amplification, target, multiplex, first 2 nucleic acid sequences

83904 x 4-Mutation identification by DNA sequencing, single segment, each segment

83909 x 4-Separation and identification by high resolution technique

 

HIF2A Gene, Mutation Analysis, B

83900-Amplification, target, multiplex, first 2 nucleic acid sequences

83904 x 4-Mutation identification by DNA sequencing, single segment, each segment

83909 x 4-Separation and identification by high resolution technique

 

PHD2 Gene, Mutation Analysis, B

83900-Amplification, target, multiplex, first 2 nucleic acid sequences

83901 x 3-Amplification, target, multiplex, each additional nucleic acid sequence beyond 2

83904 x 12-Mutation identification by DNA sequencing, single segment, each segment

83909 x 12-Separation and identification by high resolution technique

 

 

VHL Full Gene Analysis (if appropriate)

81404-VHL (von Hippel-Lindau tumor suppressor) (eg, von Hippel-Lindau familial cancer syndrome), full gene sequence

81403-VHL (von Hippel-Lindau tumor suppressor) (eg, von Hippel-Lindau familial cancer syndrome), deletion/duplication analysis (if appropriate)

 

For nonparticipating payers:

 

Von Hippel-Lindau (VHL) Gene, Full Gene Analysis

83892 x 2-Enzymatic digestion

83894-Separation by gel electrophoresis

83900-Amplification, target, multiplex, first 2 nucleic acid sequences

83901 x 4-Amplification, target, multiplex, each additional nucleic acid sequence beyond 2

83912-Interpretation and report

 

VHL Gene Sequencing

83909 x 6

 

VHL Deletion Detection

83900-Amplification, target, multiplex, first 2 nucleic acid sequences (if appropriate)

83901 x 14-Amplification, target, multiplex, each additional nucleic acid sequence beyond 2 (if appropriate)

83909-Separation and identification by high-resolution technique (if appropriate)

83914-Mutation identification by enzymatic ligation or primer extension, single segment, each segment (if appropriate)