Search our Test Catalog. Specify what to search (name, test code, titles, everywhere) and how to search (begins with, contains)

Unit Code 91759:
S-100B AccuQuant, Serum

Print Friendly View

Specimen Required

Draw blood in plain, red-top tube(s). (Serum gel tube is

acceptable.) Spin down and send 1.0 mL serum frozen in a

screw-cap vial.

Transport Temperature

Frozen\Refrig 72 hr OK\Ambient NO

Reject Due To

Specimens Other Than:                 Serum  

Anticoagulants Other Than:           None

Hemolysis:                                          Yes

Thawing:                                              Warm Reject; Cold OK

Lipemia:                                               Yes

Day(s) and Time(s) Test Performed

Monday