Test ID: FBISB
Bismuth, Blood
Specimen Type
Describes the specimen type needed for testing
Whole Blood EDTA - Metal Free (ERB)
Specimen Required
Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.
Draw blood in an EDTA metal-free royal blue top tube(s).
Send 2 mL metal-free EDTA whole blood refrigerated.
Specimen Minimum Volume
Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.
0.2 mL Note: Submission of the minimum volume results in an elevated reporting limit and inability to repeat analysis.
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
| Specimens other than | Whole blood |
| Anticoagulants other than | Royal blue-top EDTA (metal-free) |
| Hemolysis | NA |
| Thawing | NA |
| Lipemia | NA |
| Icteric | NA |
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.
| Specimen Type | Temperature | Time |
|---|---|---|
| Whole Blood EDTA - Metal Free (ERB) | Refrigerated (preferred) | |
| Ambient | 72 hours | |
| Frozen | ||