Mobile Site ›

Print Friendly View

Test ID: VUR
Vanadium, Random, Urine

Specimen Type Describes the specimen type needed for testing

Urine

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Container/Tube: Plastic, 6-mL urine tube or a clean, plastic aliquot container with no metal cap or glued insert

Specimen Volume: 2 mL

Collection Instructions:

1. Collect a random urine specimen in a clean, plastic urine collection container.

2. See Metals Analysis-Collection and Transport in Special Instructions for complete instructions.

Additional Information: High concentrations of gadolinium and iodine are known to interfere with most metals tests. If either gadolinium- or iodine-containing contrast media has been administered, a specimen should not be collected for 96 hours.

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

0.4 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis NA
Lipemia NA
Icterus NA
Other NA

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
UrineRefrigerated (preferred)7 days
 Frozen 7 days
 Ambient 7 days