Mobile Site ›

Test Catalog

Test ID: ALDS    
Aldosterone, Serum

Specimen Type Describes the specimen type needed for testing


Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

Collection Container/Tube:

Preferred: Red top

Acceptable: Serum gel

Submission Container/Tube: Plastic vial

Specimen Volume: 1.2 mL

Collection Instructions: 8 a.m. draw time (after the patient is active for 2 hours) is recommended; preferably no later than 10 a.m.  

Additional Information: See Renin-Aldosterone Studies in Special Instructions for more detailed instructions.

Forms: If not ordering electronically, complete, print, and send 1 of the following forms with the specimen:

Cardiovascular Test Request Form (T724) (

General Request Form (T239) (

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

0.6 mL

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected


Mild OK; Gross OK


Mild OK; Gross OK


Mild OK; Gross OK



Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
SerumFrozen (preferred)30 days
 Refrigerated 7 days
 Ambient 4 days