Test ID: SCADK
Short-Chain Acyl-CoA Dehydrogenase (SCAD) Deficiency, Known Mutation
Specimen Type
Describes the specimen type needed for testing
Specimen Required
Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.
This test can only be performed if a mutation has previously been identified in a family member of this individual.
Forms:
1. New York Clients-Informed consent is required. Please document on the request form or electronic order that a copy is on file. An Informed Consent for Genetic Testing (Supply T576) is available in Special Instructions.
2. Molecular Genetics-Biochemical Disorders Patient Information Sheet (Supply T527) in Special Instructions
3. If not ordering electronically, submit a Molecular Genetics Request Form (Supply T245) with the specimen.
Specimen must arrive within 96 hours of collection.
Submit only 1 of the following specimens:
Preferred:
Specimen Type: Whole blood
Container/Tube:
Preferred: Lavender top (EDTA) or yellow top (ACD)
Acceptable: Any anticoagulant
Specimen Volume: 3 mL
Collection Instructions:
1. Invert several times to mix blood.
2. Send specimen in original tube.
Specimen Stability Information: Ambient (preferred)/Refrigerated
Specimen Type: Cultured fibroblasts
Container/Tube: T-25 flask
Specimen Volume: 2 full flasks
Specimen Stability Information: Ambient (preferred)/Refrigerated 24 hours
Specimen Type: Blood spots
Container/Tube: Whatman Protein Saver 903 Paper
Specimen Volume: 5 blood spots
Collection Instructions:
1. Let blood dry on the filter paper at ambient temperature in a horizontal position for 3 hours.
2. Do not expose specimen to heat or direct sunlight.
3. Do not stack wet specimens.
4. Keep specimen dry.
Specimen Stability Information: Ambient (preferred)/Refrigerated
Specimen Minimum Volume
Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
No specimen should be rejected. If specimen is received in wrong anticoagulant or at an inappropriate temperature, include note to lab. If questions, contact lab.
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.
| Specimen Type | Temperature | Time |
|---|---|---|
| Varies | Varies | |