Test ID: C8FX
C8 Complement, Functional, Serum
Specimen Type
Describes the specimen type needed for testing
Serum Red
Specimen Required
Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.
Collection Container/Tube: Red top
Submission Container/Tube: Plastic vial
Specimen Volume: 1 mL
Collection Instructions:
1. Immediately after drawing the specimen, place the tube on wet ice.
2. Spin down and separate serum from clot.
3. Immediately freeze specimen.
Additional Information: Fasting preferred.
Specimen Minimum Volume
Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.
0.5 mL
Reject Due To
Identifies specimen types and conditions that may cause the specimen to be rejected
| Hemolysis | Mild OK; Gross OK |
| Lipemia | Mild OK; Gross reject |
| Icterus | Mild OK; Gross OK |
| Other | Serum gel tube |
Specimen Stability Information
Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.
| Specimen Type | Temperature | Time |
|---|---|---|
| Serum Red | Frozen | 14 days |