Mobile Site ›
Print Friendly View

Test ID: VLCKM    
Very Long Chain Acyl-CoA Dehydrogenase Deficiency, Known Mutation

Specimen Type Describes the specimen type needed for testing

Varies

Specimen Required Defines the optimal specimen. This field describes the type of specimen required to perform the test and the preferred volume to complete testing. The volume allows automated processing, fastest throughput and, when indicated, repeat or reflex testing.

This test can only be performed if a mutation has previously been identified in a family member of this individual.

 

Forms:

1. Molecular Genetics-Biochemical Disorders Patient Information Sheet (Supply T527) in Special Instructions

2. New York Clients-Informed consent is required. Please document on the request form or electronic order that a copy is on file. An Informed Consent for Genetic Testing (Supply T576) is available in Special Instructions.

3. If not ordering electronically, submit a Molecular Genetics Request Form (Supply T245) with the specimen.

 

Specimen must arrive within 96 hours of collection.

 

Submit only 1 of the following specimens:

 

Preferred:

Specimen Type: Blood

Container/Tube: Lavender top (EDTA) or yellow top (ACD)

Specimen Volume: 3 mL

Collection Instructions:

1. Invert several times to mix blood.

2. Send specimen in original tube.

Specimen Stability Information: Ambient (preferred)/Refrigerated

 

Acceptable:

Specimen Type: Blood spots

Container/Tube: Whatman Protein Saver 903 Paper

Specimen Volume: 5 blood spots

Collection Instructions:

1. Let blood dry on the filter paper at ambient temperature in a horizontal position for 3 hours.

2. Do not expose specimen to heat or direct sunlight.

3. Do not stack wet specimens.

4. Keep specimen dry.

Specimen Stability Information: Ambient (preferred)/Refrigerated

 

Specimen Type: Cultured fibroblasts

Container/Tube: T-75 or T-25 flask

Specimen Volume: 1 full T-75 or 2 full T-25 flasks

Specimen Stability Information: Ambient (preferred)/Refrigerated <24 hours

 

Specimen Minimum Volume Defines the amount of specimen required to perform an assay once, including instrument and container dead space. Submitting the minimum specimen volume makes it impossible to repeat the test or perform confirmatory or perform reflex testing. In some situations, a minimum specimen volume may result in a QNS (quantity not sufficient) result, requiring a second specimen to be collected.

Blood: 1 mL/Blood Spots: 3

Reject Due To Identifies specimen types and conditions that may cause the specimen to be rejected

Hemolysis

NA

Lipemia

NA

Icterus

NA

Other

NA

Note: No specimen should be rejected. If specimen is not received at the appropriate temperature or in the wrong anticoagulant, include note to laboratory. Contact laboratory with questions.

Specimen Stability Information Provides a description of the temperatures required to transport a specimen to the laboratory. Alternate acceptable temperature(s) are also included.

Specimen TypeTemperatureTime
VariesVaries