Test ID: QHBV
Hepatitis B Virus DNA Quantification by bDNA, Serum
Method Description
Describes how the test is performed and provides a method-specific reference
The VERSANT HBV DNA 3.0 Assay (bDNA) is based on a target signal amplification method for the quantification of hepatitis B virus (HBV) DNA in human serum and plasma. In an overnight incubation, HBV DNA is liberated from virions, and its capture to a microwell is mediated by a set of specific, synthetic oligonucleotide capture probes (capture extenders). A set of target probes (label extenders) is also hybridized to the viral DNA during this incubation step. The 2 sets of target probes bind to conserved regions of the S and C genes of the HBV genome. These target probes have been specifically designed to capture and quantify all HBV genotypes equally. After overnight incubation, the preamplifier and amplifier probes are hybridized to the target probes (label extenders). Multiple copies of an alkaline phosphatase-conjugated probe (label probe) are then hybridized to the immobilized complex. Detection is achieved by incubating the complex with a chemiluminescent substrate and measuring the light emission generated by the bound alkaline phosphatase reacting with the chemiluminescent substrate. Light emission is directly proportional to the amount of HBV DNA present in each specimen. Results are recorded as relative light units by the VERSANT 440 Molecular System. A standard curve is defined by light emission from 5 analytical standards containing known concentrations of recombinant bacteriophage. Concentrations of HBV DNA in specimens are then determined from this standard curve.(Package insert: VERSANT HBV DNA 3.0 Assay [bDNA], Siemens Healthcare Diagnostics Inc., Tarrytown, NY, 06868486 Rev. A, 2007-12)
Day(s) and Time(s) Test Performed
Outlines the days and times the test is performed. This field reflects the day and time the sample must be in the testing laboratory to begin the testing process and includes any specimen preparation and processing time required before the test is performed. Some tests are listed as continuously performed, which means assays are performed several times during the day.
Monday through Friday; 12 p.m.


