Unit Code 91172:
Immune Complex Expanded Panel
Reference Values
Polyethylene Glycol (PEG) IgG
REFERENCE RANGE: < 3.5 mg/dL
INTERPRETIVE CRITERIA:
< 3.5 mg/dL Normal level
> or = 3.5 mg/dL Elevated level
The PEG method is both antigen and antibody non-specific
and is based on the property of immune complexes to
precipitate at low concentrations of PEG (2.5-3.5%). The
PEG method will precipitate immune complexes of various
sizes and composition as well as other macromolecules
present in serum. Elevated serum IgG may cause a false
positive increase in the PEG precipitate.
Test Performed by: Focus Diagnostics, Inc
5785 Corporate Avenue
Cypress, CA 90630-4750
Immune Complex, C1q
REFERENCE RANGE: <4.4 Negative
4.4 - 10.7 Equivocal
>=10.8 Positive
Test Performed by: Quest Diagnostics Nichols Institute
33608 Ortega Highway
San Juan Capistrano, CA 92690-6130
C3d Immune Complex
REFERENCE RANGE: 0 - 8 Negative
Test Performed by: Quest Diagnostics Nichols Institute
33608 Ortega Highway
San Juan Capistrano, CA 92690-6130
C3, NEPH
REFERENCE RANGE: 83-239 mg/dL
C4, NEPH
REFERENCE RANGE: 10-63 mg/dL
Test Performed by: Focus Diagnostics, Inc.
5785 Corporate Avenue
Cypress, CA 90630-4750