Bacterial Identification by Matrix-Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry
MALDI TOF Mass Spectrometry: Strengths
February 2012
In summary, matrix-assisted laser desorption ionization mass spectrometry is automated, green, doesn't require specific expertise in mass spectrometry, and has a rapid turnaround time and high throughput capability. It only requires a single colony and is associated with a low exposure risk due to sample inactivation. Although not covered in today's presentation, this approach is cost effective and has demonstrated high interlaboratory reproducibility. It has broad applicability (covering all types bacteria including anaerobes, and fungi). The system is open and adaptable by the user.
MALDI TOF Mass Spectrometry: Strengths |
Jump to section:
- Introduction
- Objectives
- How Does Mass Spectrometry Work?
- Types of Mass Spectrometry
- Matrix-Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry
- Matrix-Assisted Laser Desorption Ionization Time of Flight Mass Spectrometry - Bruker Biotyper
- Matrix-Assisted Laser Desorption Ionization
- Matrix-Assisted Laser Desorption Ionization
- Matrix-Assisted Laser Desorption Ionization
- Time of Flight
- Mass Spectrum Generated Compared with Library (Database)
- Commercial MALDI TOF Systems for Microbial Identification
- MALDI TOF Mass Spectrometry Preparatory Extraction*
- Bacterial Identification by Mass Spectrometry
- Bacterial Identification by MALDI TOF Mass Spectrometry1
- Bruker Biotyper MALDI TOF Mass Spectrometry versus BD Phoenix Automated Microbiology System Identification of Gram-Negative Bacilli2
- Bruker Biotyper MALDI TOF Mass Spectrometer versus BD Phoenix Automated Microbiology System Identification of Gram-Negative Bacilli2
- Bruker Biotyper MALDI TOF Mass Spectrometer versus BD Phoenix Automated Microbiology System Identification of Gram-Negative Bacilli2
- Bruker Biotyper MALDI TOF Mass Spectrometer versus BD Phoenix Automated Microbiology System Identification of Gram-Negative Bacilli2
- Bruker Biotyper MALDI TOF Mass Spectrometer versus BD Phoenix Automated Microbiology System Identification of Gram-Negative Bacilli2
- Bruker Biotyper MALDI TOF Mass Spectrometer versus BD Phoenix Automated Microbiology System Identification of Gram-Negative Bacilli2
- Identification of Gram-Positive Cocci by Bruker Biotyper Mass Spectrometry3
- Identification of Gram-Positive Cocci by Bruker Biotyper Mass Spectrometry3
- Gram-Positive Cocci3
- Gram-Positive Cocci3
- Misidentification by Bruker Biotyper3
- MALDI TOF Mass Spectrometry: Strengths
- MALDI TOF Mass Spectrometry: Limitations
- Bacteriology Laboratory Workflow Today
- Workflow with Mass Spectrometry
- References
- Acknowledgments
- Questions